Probe Store - True Non Contact Mode
* We do not guarantee the performance of probes ordered directly from the manufacturer; for optimal performance with our AFM systems please request a quote from Park Systems.
Probe | Force Constant (N/m) | Frequency (kHz ) | Manufacture | Short Description | Quote | ||||||||||||||||||
PPP-NCHR | 42 | 330 | Nanosensors | ▪ Non-contact cantilever with high resonant frequency ▪ Backside reflex coating |
Request Quote | ||||||||||||||||||
The reflex coating is an approximately 30 nm thick aluminum coating on the detector side of the cantilever which enhances the reflectivity of the laser beam by a factor of about 2.5. Furthermore it prevents light from interfering within the cantilever. The virtually stress-free coating is bending the cantilever less than 3.5% of the cantilever length.
|
|||||||||||||||||||||||
SSS-NCHR | 42 | 330 | Nanosensors | ▪ Non-contact cantilever with high resonant frequency, backside reflex coating ▪ Tip visibility from top |
Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
PPP-NCH | 42 | 330 | Nanosensors | ▪ Non-contact cantilever with high resonant frequency | Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
SSS-NCLR | 48 | 190 | Nanosensors | ▪ Non-contact cantilever with low resonant frequency of ~ 200 kHz ▪ Backside reflex coating |
Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
PPP-NCLR | 48 | 190 | Nanosensors | ▪ Non-contact cantilever with low resonant frequency of ~ 200 kHz ▪ Backside reflex coating |
Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
PPP-NCL | 48 | 190 | Nanosensors | ▪ Non-contact cantilever with low resonant frequency of ~ 200 kHz | Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
SSS-NCL | 48 | 190 | Nanosensors | ▪ Non-contact cantilever with low resonant frequency of ~ 200 kHz ▪ Tip radius: 2 nm typical, < 5 nm max. |
Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
NSC15 | 40 | 325 | Mikromasch | ▪ Non-contact cantilever ▪ Backside reflex coating |
Request Quote | ||||||||||||||||||
Cantilevers of the 15 series are generally used in tapping mode for imaging hard samples, when high topographic and phase contrast are necessary. The 15 series is also good for non-contact AFM.
|
|||||||||||||||||||||||
AR5-NCH | 42 | 330 | Nanosensors | ▪ Noncontact cantilever with High aspect ratio tip, Backside reflex coating ▪ Typical aspect ratio of the tip is 7:1 |
Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
AR5-NCHR | 42 | 330 | Nanosensors | ▪ Noncontact cantilever with High aspect ratio tip, Backside reflex coating ▪ Typical aspect ratio of the tip is 7:1 |
Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
AR5T-NCHR | 42 | 330 | Nanosensors | ▪ Noncontact cantilever with High aspect ratio tip, Backside reflex coating ▪ Typical aspect ratio of the tip is 7:1, and the tip is tilted 13°. |
Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
AR10-NCH | 42 | 330 | Nanosensors | ▪ Noncontact cantilever with High aspect ratio tip ▪ Typical aspect ratio of the tip is 12:1 |
Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
AR10-NCHR | 42 | 330 | Nanosensors | ▪ Noncontact cantilever with High aspect ratio tip ▪ Typical aspect ratio of the tip is 12:1 |
Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
AR10T-NCHR | 42 | 330 | Nanosensors | ▪ Noncontact cantilever with High aspect ratio tip, Backside reflex coating ▪ Typical aspect ratio of the tip is 12:1, and the tip is tilted 13° |
Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
CNT-NCH | 42 | 330 | Nanosensors | ▪ Noncontact cantilever with Carbon nanotube tip ▪ Length of the CNT tip: < 750 nm. |
Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
OMCL-AC160TS | 26 | 300 | Olympus | ▪ Non-contact cantilever with high resonant frequency, backside reflex coating ▪ Tip visibility from top |
Request Quote | ||||||||||||||||||
|
|||||||||||||||||||||||
ATEC-NC | 45 | 335 | Nanosensors | ▪ Non-contact cantilever ▪ Tip visibility from top |
Request Quote | ||||||||||||||||||
These tips are designed for non-contact or tapping mode imaging. They feature a tetrahedral tip that protrudes from the very end of the cantilever allowing it to be the only probe to offer real tip visibility from the top even if the probe is tilted.
|
|||||||||||||||||||||||
ACTA | 40 | 300 | AppNano | ▪ Non-contact cantilever ▪ Backside reflex coating |
Request Quote | ||||||||||||||||||
|